Telemecanique - XPSUAT13A3AP
XPS-AR311144 is supported by the
Manufacturer replaced as follows:
XPSUAT13A3AP
Preventa XPS Universal safety relay.
Multifunctional safety relay for diverse
Security application thanks to selectable
Safety function and start option on the front
Rotary switch and diagnostic communication to the PLC.
Suitable for mechanical contacts in emergency stop / stop,
Position or magnetic switches, step mats as well
electronic PNP / NPN sensors, light curtain or
RFID safety switch with OSSD outputs.
Selectable start function automatic, manual or
monitored start and start-up test. number
Safety circuits 1 (redundant) - Selectable
Safety function 1 of 10. Outputs safe relays
3S instantaneous + 3S optionally delayed + 1NC - Status 1T -
Diagnosis 1T. Safe switch-off delay 0.1 seconds
up to 15 minutes for SS1 or Stop1 function. Clocked
The output transmits extensive diagnostic data to the
PLC to standard input and evaluation via FB.
Safety level PL e, Cat. 4, SIL3.
Supply voltage 24 VAC / DC. connections
removable screw terminals. Side connector
for the direct connection of contact expansion without