Version SGCR regular operation
Shock version 0 without
set to 90 in degrees
Valve connection F10-N ISO 5211 without centering
Coupling type ST-A steel with one-sided axial lock
Coupling dimension S-22 S, square SW=22mm EN ISO 5211 with threaded pin
Actuating time 32 in seconds for 90° S8-4
Operating mode 2 S4 - 40%
Torque 200-500 Adjustment range 200-500 Nm
adjusted to 500 Nm in direction of rotation S7-8
adjusted to 500 Nm in direction of rotation S6-8
temperature version N-25-70 -25C - +70C
Corrosion protection KS-P1.001 powder coating,
primer, top coat
Color A0001 AUMA silver-grey
Degree of protection IP68
Hand wheel 160-3-000-B000 mm with ball handle
Mains voltage 230/50/1 230V 50Hz 1ph AC
Mechanical Position Display 11
Wiring diagram 50R200-0A0-000 TPA
Profinet -
Power unit B40.01 power electronics
Interface D00.01 Parallel
Input signals R20.02 MODE, CLOSE, OPEN, STOP
Control voltage E00.01 24 V DC
max. 28VDC 12mA
Signaling relay H20.02 Contacts: 2 NO 5A, 2 NO 1A 1 analogue output
Output signals S20.01 end position CLOSED/OPEN, fault, REMOTE
Analog input 1 P20.02 setpoint: 4-20mA
Analog output 1 P00.02 actual position: 4-20mA
Voltage tolerance A40.01 +/- 10%
Local controls L40.01 OPEN, STOP (LOCAL-REMOTE), CLOSE
Indicator light L50.01 CLOSED: yellow, OPEN: green, LOCATION: blue,
ERROR/FAULT: red
Shutdown TO 042.01 way
S10-1 path dependent; Slide switch at the white dot
Shutdown ON 043.01 way
S10-1 path dependent; Slide switch at the white dot
Electrical connection S0-105 M20;M25;M32 plug
angle/protective cap 0 -/-
Wiring diagram TPC B-1H6-2C7-0000
Nameplate DE-AL German, aluminium
Operating instructions EN German
Test according to KV KV06.03.027.00 inspection certificate