Burkert - BU-054718
Device function mass flow controller (MFC)
Type 8746
Supply voltage 24 V DC
Typical electrical power consumption 3.0 W.
Signal type analog
Input signal 4-20 mA
Output signal 4-20 mA
Electrical connection 1 plug - M12
Line connection thread G 1/2 "
Fluid housing made of aluminum
Seal material FKM (fluororubber)
Valve type 3280
Nominal seat width 5 mm (3/16 ")
Seat seal material FKM (fluororubber)
Max. Valve pressure 22 bar
Measurement accuracy of the measured value 2.00%
Measurement accuracy of the final value 0.50%
Measuring or control span 1:50
Degree of protection IP54
Design data
Reference conditions T = 0 ° C, P = 1.013 bar (a) (Ref. N)
Gas name Ar - argon
Calibration medium 1 operating gas
Nominal flow rate 1,000.00 l / min
Max. Pressure at the inlet 14.00 bar (g)
Operating pressure at the inlet 8.00 bar (g)
Outlet pressure medium 1 at Qne 2,000 bar (g)
Gas temperature 25 ° C
Ambient temperature 25 ° C
Installation position horizontal
kV value of the application [m3 / h] 0.59821 m3 / h