Delimon - 662023501
Electronical Control and Monitoring Device for
Progressive Systems
Inputs :
Connection
A1 and A2 operating voltage 110 ... 127 V 50 ... 60 Hz ± 10 %
A1 and A3 operating voltage 220 ... 240 V 50 ... 60 Hz ± 10 %
B1 (+) and B2 (-) operating voltage 24 V DC ± 10 %
Connection
C1 (+) and C2 (-) Mains voltage 24 V DC for connections 1 to 5, in case the unit is to be actuated with
AC single phase, or unfiltered DC.
Connection
D1 (+) and D2 (-) If there is DC 9 V up to 24 V present, in case of operating voltage drop the
pulse-store will be buffered.
Connection
D2 (-) and Z1 Bridging these connections makes the post running time for dividers (during pause
time) inoperative.
Connection 1 Pause addition or pulse monitoring
According to pause adjustment times may be added or pulses counted.
Pause adjustment 1 ... 9999 pulses or
1 ... 9999 seconds or
1 ... 9999 minutes
With pulse independent monitoring the lubrication process must be completed prior
to the adjusted number of p