Krone Filter Solutions Gmbh - Filter Angaben:
Self-cleaning automatic filter, type KAF - Bernoulli DN 300
GGG-50, EN-GJS-500-7, 2.5 mm rubberized
Connections:
Nominal size: DN 30 DIN EN 1092-1 PN 10
Flushing outlet: DN 100 DIN EN 1092-1 PN 16
Operating conditions:
Medium: sea water
Operating pressure: Unknown (min. 0.6 bar during flushing)
Design pressure: 6 bar
Design temperature: 0 / + 80 ° C
Operating temperature: Unknown
Flow rate: 560 m³ / h
Backwash quantity: 1.5 m³
Backwashing time: approx. 42 seconds
Pressure loss clean: approx. 0.07 bar
Differential pressure flushing: 0.11 bar + pressure loss clean
Materials:
Filter housing: GGG-50, EN-GJS-500-7
External parts: galvanized steel
Inner parts: SS 316Ti
Seals: NBR
Filter element:
Siebart: Edge gap sieve / basket sieve - perforated plate
Filter fineness: 300 μm / 0.3 mm
Material: SS 316
Perm. Differential pressure: 1 bar
Equipment:
Differential pressure switch: Aplisens, membrane made of Hastelloy
Flush valve: DN 100, wetted parts duplex 1.4462 / 1.4469,
pneum. drive
Control:
SPS - Crouzet Millenium III
Supply voltage: 230V AC, 1 Ph, 50 Hz
Control voltage: 24 V DC
Corrosion protection:
Inside: 2.5 mm rubberized Chemonit 33
Outside: epoxy RAL 5010
Interpretation:
Classification and conformity assessment according to PED 2014/68 / EU
Design based on AD2000