Rheonik - RHM15L-N1-P2-SM0-M1-G1-JM-NN-NN-SE-N-A
Sensor model RHM
N1 temperature: normal temperature (NT)
-20 to +120°C
P2 operating pressure max. 300 bar at 120°C
Measuring tubes: (larger wall thicknesses reduce
the measuring range and
increase the pressure loss)
SM0 measuring tubes: Serial arrangement, removable
Connection block with PTFE
seals, Pmax. 230 bar,
with flange connection 214bar.
Measuring ranges with serial
Pipe guide halved.
M1 material: measuring tubes DIN 1.4571,
process connection DIN 1.4571.
G1 process connection: internal thread G 3/4",
(only with PMO/PHO/SMO/PFT)
JM connection housing: cast aluminum coated,
Cable entry M25 or M20
or ½" or ¾", (2 x Pt1000)
Only for Ex version. NN, 2A, A1,
C0.
For externally mounted RHE2x
NN Option: Without option
NN Ex protection: none
SE design: manufacturer standard according to EN
SEP (Common Engineering Practice)
according to DGRL Art.3 Section 3,
On request, the corresponding
Manufacturer's declaration (certificate)
available at extra cost.
N Service: no special services
A Cal. Accuracy: Standard Accuracy 0.2%
3 points (RHE 16 or higher,
otherwise 0.5%)