266DRH differential pressure transmitter, with pressure sensor with capillary tube, basic accuracy 0.075%, static pressure dependent on pressure sensor / sensor limits

266DRH.F.S.R.R.S.B.1 - .. E2..L1.B2..S2 ... I2
Included:
S26WE.H.P5.F.TM.2.B.C.N.N.N.N 5 S26WE EN Flat pressure sensor in cell design
S26WE.L.P5.F.TM.2.B.B.S.N.N.N 5 S26WE EN Flat pressure sensor in cell design
266DRH
- Sensor measuring range limits / F 0.67 and 40 kPa (6.7 and 400 mbar, 2.67
Basic accuracy and 160 in, H2O) / 21 MPa (210 bar, 3045
psi) / basic accuracy 0.06%
- Static pressure S Permissible working pressure: Standard
- Membrane material / filling liquid R AISI 316L ss (not wetted) / Silicone oil
(NACE) for two seals construction
(direct + remote or remote + remote)
- Process flange and adapter material / R AISI 316L stainless steel / With two
Pressure sensor connections (NACE)
- Screws material / seals S Stainless steel (AISI 316 SST) / Without
Material seals, when connecting a second
Pressure sensor
- Housing material / Electrical B aluminum alloy (barrel type) / M20 x 1.5
connection
- Output 1 HART digital communication and 4 ... 20 mA
- Explosion protection E2 ATEX flameproof enclosure Ex d
- Integrated digital display (LCD) L1 Integrated LCD display with integrated
Keys
- Fastening accessories / material B2 for pipe or wall mounting /
Stainless steel AISI 316 (1.4401)
- Overvoltage protection S2 With overvoltage protection (transient
Protector)
- Additional identification label I2, measuring point and certification label
stainless steel, laser printing
- Dual Use NA: no Export Authorization required
- Feasibility check on diaphragm seal Manufacturable solution
Abb - 266DRH.F.S.R.R.S.B.1-..E2..L1.B2..S2...I2

266DRH differential pressure transmitter, with pressure sensor with capillary tube, basic accuracy 0.075%, static pressure dependent on pressure sensor / sensor limits 266DRH.F.S.R.R.S.B.1 - .. E2..L1.B2..S2 ... I2 Included: S26WE.H.P5.F.TM.2.B.C.N.N.N.N 5 S26WE EN Flat pressure sensor in cell design S26WE.L.P5.F.TM.2.B.B.S.N.N.N 5 S26WE EN Flat pressure sensor in cell design 266DRH - Sensor measuring range limits / F 0.67 and 40 kPa (6.7 and 400 mbar, 2.67 Basic accuracy and 160 in, H2O) / 21 MPa (210 bar, 3045 psi) / basic accuracy 0.06% - Static pressure S Permissible working pressure: Standard - Membrane material / filling liquid R AISI 316L ss (not wetted) / Silicone oil (NACE) for two seals construction (direct + remote or remote + remote) - Process flange and adapter material / R AISI 316L stainless steel / With two Pressure sensor connections (NACE) - Screws material / seals S Stainless steel (AISI 316 SST) / Without Material seals, when connecting a second Pressure sensor - Housing material / Electrical B aluminum alloy (barrel type) / M20 x 1.5 connection - Output 1 HART digital communication and 4 ... 20 mA - Explosion protection E2 ATEX flameproof enclosure Ex d - Integrated digital display (LCD) L1 Integrated LCD display with integrated Keys - Fastening accessories / material B2 for pipe or wall mounting / Stainless steel AISI 316 (1.4401) - Overvoltage protection S2 With overvoltage protection (transient Protector) - Additional identification label I2, measuring point and certification label stainless steel, laser printing - Dual Use NA: no Export Authorization required - Feasibility check on diaphragm seal Manufacturable solution