12150071 Compressors with ester oil semi-hermetic, single-stage, suction gas-cooled, 400/3/50, part wrap start
1200FT LBS
11. pages
-100-125AL (563830 Power distribution terminal block ERIFLEX Spec.: (TD-100-125AL (563830
1. 90/100 KG 2. 110/120 KG 3. 115/135 KG 4. 335/45 KG 5. 45/55 KG 6. 190/200 KG
1" Port, 2-70, 3-80 LPM, PPS Flowmeter
1- It will be hydraulic motor driven. The CO2 pump of the system will be hydraulically driven. The hydraulic unit that provides the pump drive will be able to be placed in a different section to meet the GMP and fire safety requirements. 2- It should be suitable for liquid-liquid operation. 3- It must be piston type. 4- Piston monitoring system should be available. 5- It should have a minimum flow rate of 180 kg/hour and a maximum flow rate of 240 kg/hour. 6- Working pressure should be maximum 350 Bar. Safety valves must be in compliance with this condition and international standards. 7- It should be able to work with 1% dosing precision. 8- The hydraulic oil reservoir must be at least 100 liters. 9- It should include hydraulic oil cooling and filtering system. 10- It should be a pallet type hydraulic pump. 11- It should contain long-lasting solenoid valves that provide metal-to-metal sealing. 12- There should be a double ball check valve system. 13- Electrohydraulic flow-pressure control valve should be available for precise flow and pressure control. 14- Stroke must be adjusted and it must be automatically adjustable. 15- There should be a safety valve and a rupture disc on it. 16- It should be at least 5.5 kW.
1- It will be driven by compressed air or electric motor. If an electric driven motor is to be used, it must be in IE3 class. 2- It should be suitable for liquid-liquid operation. 3- The pump must be Pneumatic or Diaphragm type. If the pump is diaphragm type, it should be double-layered (sandwich technology) and Teflon (PTFE) material. 4- There should be a diaphragm monitoring system. 5- It should have a maximum flow of 20 kg/hour. 6- Working pressure should be minimum 300 and maximum 350 Bar. 7- It should be able to work with 1% dosing precision. 8- Frequency converter must be controlled. 9- There should be a double ball check valve system. 10- It should be isocratic controlled. 11- Stroke adjustment should be available and it should be manually adjustable. 12- There should be a safety valve and a rupture disc on it. 13- Minimum 1.5 kW. 14- Zone 2 class must have ATEX certificate.
1 IMPACT WRENCH 1550 FT-LBS
1 IMPACT WRENCH
063000012 Motor