"Meinberg" markasına ait modeller;
Ref. 23092804 
NTP time server with ultra-stable integrated oscillator OCXO-HQ *)
and Intelligent Reference Selection Algorithm (IRSA)
Intelligent switching between available synchronization sources:
GPS, Time Code (e.g. IRIG-B), Pulse Per Second (PPS), 10MHz or
external NTP servers.
4 x LAN interface 10/100 MBit, RJ45 connector
1 x Terminal RS232 interface, 9pin D-Sub male connector
for initial setup and configuration
1 x USB Service interface
1 x LC-Display (2 x 40 characters) and 8 push buttons
----------------------------------------------------------------------------------------------
Reference Inputs:
1 x Meinberg GPS antenna input, BNC connector, isolated
1 x PPS input, TTL, pulse duration >= 5µs, active high, female BNC connector
1 x 10 MHz input, sine (1.5Vpp - 5Vpp) or TTL, female BNC connector
1 x Time Code modulated input, BNC connector, isolated by transformer
Insulation voltage 3000 VDC
Input impedance: 50 Ohm, 600 Ohm, 5 kOhm
Internally selectable by jumper (default 600 Ohm)
Input signal : 600mV to 8 V (Mark, peak-to-peak)
1 x Time Code unmodulated input, BNC connector, isolated by opto-coupler
Insulation voltage : 3750 Vrms
Internal series resistor : 330 Ohm,
Max. input current : 25 mA
Diode forward voltage : 1.0 V...1.3 V
selectable Time Code Inputs, modulated / unmodulated (DCLS):
B122/123 / B002/003
B126/127 / B006/007
IEEE1344 (modulated and DCLS)
AFNOR NFS 87-500 (modulated and DCLS)
----------------------------------------------------------------------------------------------
Signal Outputs:
2 x RS232 interface, independent, 9pin D-Sub female connector,
with multi data formats timestrings.
1 x PPS, TTL into 50 ohm, pulse duration 200 msec,
active high, female BNC connector
1 x Standard Frequency 10 MHz, TTL into 50 ohm, female BNC connector
1 x Alarm Relay Output, change-over contact, 3pin DFK connector
1 x Time Code AM, amplitude modulated sinewave output (e.g. IRIG-B12x) ,
3 Vpp into 50 ohm, via female BNC connector
1 x Time Code DCLS, Pulse-width modulated output (e.g. IRIG-B00x),
TTL active high, via female BNC connector
(AM and DCLS Time Code signals are generated in parallel )
additionally Time Codes available: IEEE1344 und AFNOR NFS 87-500.
1 x PPM, TTL into 50 ohm, pulse duration 200 msec,
active high, female BNC connector
1 x Synthesizer for frequencies from 0,1 Hz up to 10 MHz,
TTL into 50 ohm, female BNC connector
----------------------------------------------------------------------------------------------
Technical specifications:
Power supply:
Unom: 100-200 V DC / 100-240 V AC (50-60 Hz) //
Umax: 90-250 V DC / 90-265 V AC (50-60 Hz)AC (50-60 Hz)
Power consumption: max. 30 W
19" metal chassis, 1 U/84 HP
(483 mm wide x 43 mm high x 285 mm deep)
----------------------------------------------------------------------------------------------
Scope of supply:
The system will be delivered inclusive of GPS/Converter
outdoor antenna, mounting kit and 100m coax-cable (RG58).
LANTIME M320/MRS/LNE/TC-1-1/PPM-1/FSS-1/AD10

Meinberg
Ref. 23092804 NTP time server with ultra-stable integrated oscillator OCXO-HQ *) and Intelligent Reference Selection Algorithm (IRSA) Intelligent switching between available synchronization sources: GPS, Time Code (e.g. IRIG-B), Pulse Per Second (PPS), 10MHz or external NTP servers. 4 x LAN interface 10/100 MBit, RJ45 connector 1 x Terminal RS232 interface, 9pin D-Sub male connector for initial setup and configuration 1 x USB Service interface 1 x LC-Display (2 x 40 characters) and 8 push buttons ---------------------------------------------------------------------------------------------- Reference Inputs: 1 x Meinberg GPS antenna input, BNC connector, isolated 1 x PPS input, TTL, pulse duration >= 5µs, active high, female BNC connector 1 x 10 MHz input, sine (1.5Vpp - 5Vpp) or TTL, female BNC connector 1 x Time Code modulated input, BNC connector, isolated by transformer Insulation voltage 3000 VDC Input impedance: 50 Ohm, 600 Ohm, 5 kOhm Internally selectable by jumper (default 600 Ohm) Input signal : 600mV to 8 V (Mark, peak-to-peak) 1 x Time Code unmodulated input, BNC connector, isolated by opto-coupler Insulation voltage : 3750 Vrms Internal series resistor : 330 Ohm, Max. input current : 25 mA Diode forward voltage : 1.0 V...1.3 V selectable Time Code Inputs, modulated / unmodulated (DCLS): B122/123 / B002/003 B126/127 / B006/007 IEEE1344 (modulated and DCLS) AFNOR NFS 87-500 (modulated and DCLS) ---------------------------------------------------------------------------------------------- Signal Outputs: 2 x RS232 interface, independent, 9pin D-Sub female connector, with multi data formats timestrings. 1 x PPS, TTL into 50 ohm, pulse duration 200 msec, active high, female BNC connector 1 x Standard Frequency 10 MHz, TTL into 50 ohm, female BNC connector 1 x Alarm Relay Output, change-over contact, 3pin DFK connector 1 x Time Code AM, amplitude modulated sinewave output (e.g. IRIG-B12x) , 3 Vpp into 50 ohm, via female BNC connector 1 x Time Code DCLS, Pulse-width modulated output (e.g. IRIG-B00x), TTL active high, via female BNC connector (AM and DCLS Time Code signals are generated in parallel ) additionally Time Codes available: IEEE1344 und AFNOR NFS 87-500. 1 x PPM, TTL into 50 ohm, pulse duration 200 msec, active high, female BNC connector 1 x Synthesizer for frequencies from 0,1 Hz up to 10 MHz, TTL into 50 ohm, female BNC connector ---------------------------------------------------------------------------------------------- Technical specifications: Power supply: Unom: 100-200 V DC / 100-240 V AC (50-60 Hz) // Umax: 90-250 V DC / 90-265 V AC (50-60 Hz)AC (50-60 Hz) Power consumption: max. 30 W 19" metal chassis, 1 U/84 HP (483 mm wide x 43 mm high x 285 mm deep) ---------------------------------------------------------------------------------------------- Scope of supply: The system will be delivered inclusive of GPS/Converter outdoor antenna, mounting kit and 100m coax-cable (RG58).