"Rheonik" markasına ait modeller;
Coriolis mass flow meters for liquids and gases

Measuring point data (please complete):
Medium: various gases
(please specify)
Flow rate: 250 kg/h and
150 kg/hr
Pressure: 300 bars
Temperature: please specify
Density: please specify
Viscosity: please specify
We recommend to add the missing measuring point data
supplement , otherwise not for a flawless
Device design can be guaranteed.
Coriolis transducer
Model RHM03S NEW DESIGN
type code:
RHM03S-N1-P2-PM0-10-N1-JM-T1-FK-NN-SE-A

N1 temperature: normal temperature (NT)
-20 to +120 °C
P2 operating pressure max. 577 bar at 120 °C
Measuring tubes: with material SuperDuplex.
PM0 measuring tubes: Parallel arrangement, more detachable
connection block off
SS316L
Pmax. 700 bar / 120 °C,
Temp. N1 with FKM seals
Temp.NA with FVMQ seals
(max. 1000 bar / 120 °C)
Temp. E2 with FFKM seals
(max. 300 bar / 210 °C)
10 Material: Measuring tube material Super Duplex
EN 1.4410, UNS S32750
(T min -40 °C)
N1 process connection: internal thread ¼" NPT,
max. 700 bar at 120 °C
JM connection housing: cast aluminum coated,
cable entry M20 x1.5,
not for Ex protection: A0
For externally mounted RHE2x/4x
T1 Option: Housing rotated 180°
Connections are at the top
FK option: FFKM seals instead of
Standard seals, e.g
Applications with aggressive
chemicals
NN Ex protection: none
SE design: manufacturer standard according to EN
SEP (Common Engineering Practice)
according to DGRL Art.3 Section 3.
On request, the corresponding
Manufacturer's declaration (certificate)
available at extra cost
RHM03S-N1-P2-PM0-10-N1-JM-T1-FK-NN-SE-A

Rheonik
Coriolis mass flow meters for liquids and gases Measuring point data (please complete): Medium: various gases (please specify) Flow rate: 250 kg/h and 150 kg/hr Pressure: 300 bars Temperature: please specify Density: please specify Viscosity: please specify We recommend to add the missing measuring point data supplement , otherwise not for a flawless Device design can be guaranteed. Coriolis transducer Model RHM03S NEW DESIGN type code: RHM03S-N1-P2-PM0-10-N1-JM-T1-FK-NN-SE-A N1 temperature: normal temperature (NT) -20 to +120 °C P2 operating pressure max. 577 bar at 120 °C Measuring tubes: with material SuperDuplex. PM0 measuring tubes: Parallel arrangement, more detachable connection block off SS316L Pmax. 700 bar / 120 °C, Temp. N1 with FKM seals Temp.NA with FVMQ seals (max. 1000 bar / 120 °C) Temp. E2 with FFKM seals (max. 300 bar / 210 °C) 10 Material: Measuring tube material Super Duplex EN 1.4410, UNS S32750 (T min -40 °C) N1 process connection: internal thread ¼" NPT, max. 700 bar at 120 °C JM connection housing: cast aluminum coated, cable entry M20 x1.5, not for Ex protection: A0 For externally mounted RHE2x/4x T1 Option: Housing rotated 180° Connections are at the top FK option: FFKM seals instead of Standard seals, e.g Applications with aggressive chemicals NN Ex protection: none SE design: manufacturer standard according to EN SEP (Common Engineering Practice) according to DGRL Art.3 Section 3. On request, the corresponding Manufacturer's declaration (certificate) available at extra cost