50h02-1804/0
Endress Hauser
50094542
50H02-A00A1AA0ABAD
**Promag 50H02, DN02 1/12"
Link to the product information:
www.de.endress.com/50H
Magnetic-inductive flow
Measuring device, PFA lining
additional specifications
Assignment of line 1 volume flow
Assignment of line 2 totalizer 1
Assignment of totalizer 1 volume flow
Unit totalizer 1 dm3
Assignment of totalizer 2 Volume flow
Unit totalizer 2 dm3
Assignment current output volume flow
Current range 4-20 mA HART NAMUR
Value 20 mA 0.500 dm3 / min
Time constant 3,000 s
Error behavior Current output Min. Current value
Assignment pulse output volume flow
Pulse value (per pulse) 0.00500 dm3
Pulse width 100,000 ms
Output signal passive - positive
Error behavior Pulse output Quiescent level
A process connection: not used
0 seal: not used
0 electrodes: 1.4435 / 316L
A calibration: 0.5%
1 additional examination, certificate: without
A Approval: Ex-free area
A Housing: Compact aluminum, IP67 NEMA4X
0 cable, separate version: not used
A